M55021 PART NUMBER EXAMPLE: B24C904-903-902P
|
Wire |
Conductor |
Conductor |
Color of |
Color of |
Color of |
Covering over |
| B | 24 | C | 904 | 903 | 902 | P |
| (Table 1) | (Table 2) | (Table 3) | (Table 4) | (Table 5) | ||
TABLE 1: TYPE OF WIRE
| Symbol Type |
Wire Specification |
Symbol Type | Wire Specification |
| B | M16878/1 | EE | M16878/5 (NEMA HP3) |
| C | M16878/2 | BJ | M16878/17 |
| D | M16878/3 | CJ | M16878/18 |
| E | M16878/4 (NEMA HP3) | DJ | M16878/19 |
TABLE 2: CONDUCTOR SIZE
|
Conductor Size |
Stranding |
| 30 - 26 AWG | 7 Strands |
| 24 - 12 AWG | 19 Strands |
| 10 AWG | 37 Strands |
TABLE 3: CONDUCTOR MATERIAL
|
Conductor Code |
Conductor Type |
| C | Copper |
| S | Copper Clad Steel |
| H | High Strength Copper Alloy |
TABLE 4: COLOR CODE
- For single shielded and single shielded and jacketed constructions, a dash should not be used. The color code designators for wires 2 and 3 of a twisted pair and triplet are separated by a dash. Two groups of numbers indicate a twisted pair, three groups indicate a twisted triple. Any order of color code designators is acceptable.
|
Code |
Color |
Code |
Color |
| 0 | Black | 5 | Green |
| 1 | Brown | 6 | Blue |
| 2 | Red | 7 | Violet |
| 3 | Orange | 8 | Gray |
| 4 | Yellow | 9 | White |
TABLE 5: COVERING OVER COMPONENTS
|
Symol Type |
Covering Over Finished Cable |
| U | Unjacketed and unshielded |
| P | Polyvinyl Chloride (PVC) jacket |
| F | Fluorinated Ethylene Propylene (FEP) jacket |
| J | Polyamide jacket |
| T | Polytetrafluoroethylene (PTFE) jacket |
| S | Shielded and unjacketed |
| SF | Shielded and covered with FEP jacket |
| SP | Shielded and covered with PVC jacket |
| SJ | Shielded and covered with Polyamide jacket |
| STW | Shielded and covered with wrapped PTFE jacket |
| SX | Shielded and covered with extruded PTFE jacket |